The Fieldpiece SM380V 3-Port SMAN Refrigerant Manifold with Micron Gauge is built so you can do your job easier, faster, and better. From the extremely rugged overmold casing, reinforced hook, and hermetically sealed sight glass, to the wireless capabilities, data logging, and tightness test, the SM380V has been designed as the toughest, most advanced digital refrigerant manifold on the market.
Rugged Construction The newly designed SMAN is simply strong. The heavy duty casing, reinforced hook, IP54 water-resistant design, impact resistant screen, strategically placed thermocouple ports, and hermetically sealed sight glass, all ensure the SMAN is ready to withstand the rigors of field use.
Packed with Knowledge The SM380V is designed to work the way you do with advanced features to streamline your job and provide your customers with then answers they need.
Data Logging
Stores up to 9 jobs internally
Easy download via USB port
Displays % free storage space before logging begins
Logs up to 7 days (168 continuous hours)
Tightness Test
Check for leaks after repairs or installations
View pressure differential over time
Timer tracks duration of test
Temperature compensated with SL temp to avoid false positives
Customizable
Adjust auto power off duration
Adjust back light duration
Set high and low vacuum alarms
Select each unit of measurement individually
Features:
Newly designed SMAN manifold
Replacement for SMAN300 series
Three valve manifold with micron gauge
Toughest, most advanced digital refrigerant manifold on the market
Data logging - stores up to 9 jobs internally
Wireless range of 350 feet
Impact resistant case with rugged overmolded casing
Negative Pressure Accuracy29 inHg to 0 inHg: ±0.2 inHg; 75 cmHg to 0 cmHg: ±1 cmHg
Pressure Accuracy0 Psig to 200 Psig: ±1 Psig; 200 Psig to 580 Psig: ±(0.3% of readings + 1 Psig); 0 Bar to 13.78 Bar: ±0.07 Bar; 13.78 Bar to 40.00 Bar: ±(0.3% of readings + 0.07 Bar); 0 MPa to 1.378 MPa: ±0.007 MPa; 1.378 MPa to 4.000 MPa: ±(0.3% of readings + 0.007 MPa); 0 kPa to 1378 Kpa: ±7 kPa; 1378 kPa to 4000 kPa: ±(0.3% of readings + 7 kPa)
Temperature
Sensor TypeType K thermocouple (nickel chromium/nickel aluminum)
Jack Type(3) Type K thermocouple
Range-50°F to 257°F (-46°C to 125°C), limited by thermocouple specification. Display range is -95°F to 999.9°F (-70°C to 537.0°C)
Resolution0.1°F (0.1°C)
Accuracy*Shown accuracies are after field calibration
±(1.0°F) -95°F to 200°F, ±(2.0°F) 200°F to 999.9°F; ±(0.5°C) -70°C to 93°C, ±(1.0°C) 93°C to 537.0°C
Deep Vacuum
Sensor TypeThermistor
Port Type(3) 1/4" standard NPT male flare fittings (SM380V)
(1) 3/8" and (3) 1/4" standard NPT male flare fittings (SM480V)
Range and Units50 to 9999 microns of mercury (English)
6 to 1330 pascals (Metric)
0.06 to 13.3 mBar (Metric)
50 to 9999 mTorr (Metric)
0.05 to 10 Torr (Metric, equivalent to mmHg)
Best Resolution1 micron of mercury (below 2000 microns)
1 Pascal (below 250 Pascals)
0.001 mBar (below 2.5 mBar)
1 mTorr (below 2000 mTorr)
0.001 Torr (below 2.5 Torr)
Accuracy @ 77°F (25°C)±(5% of reading + 5 microns of mercury)
±(5% of reading + 1 Pascal)
±(5% of reading + 0.01 mBar)
±(5% of reading + 5 mTorr)
±(5% of reading + 0.005 Torr)
Wireless CompatibilityLatest compatibility at www.fieldpiece.com
Job Link System Minimum Device RequirementBLE 4.0 devices running iOs 7.1 or Android Kitkat 4.4
Wireless Measurement Source AssignmentsSuction line temperature: Fieldpiece model JL3PC (set to blue)
Liquid line temperature: Fieldpiece model JL3PC (set to red)
Supply air psychrometer: Fieldpiece model JL3RH (set to blue)
Return air psychrometer: Fieldpiece model JL3RH (set to red)
Refrigerant weight scale: Fieldpiece model SRS3, SRS3P